Advanced Options - 1.1 English

Integrated Logic Analyzer (ILA) with AXI4-Stream Interface LogiCORE IP Product Guide (PG357)

Document ID
PG357
Release Date
2020-11-23
Version
1.1 English
Revision

The following figure shows the Advanced Option tab:

Figure 1. Advanced Options Tab
Enable AXI4-Stream Interface for Manual Connection to AXI Debug Hub
When enabled, this option gives an AXIS interface for the IP to connect to AXI Debug Hub.
Enable Trigger Input Interface
Check this option to enable an optional trigger input port.
Enable Trigger Output Interface
Check this option to enable an optional trigger output port.
Input Pipe Stages
Select the number of registers you want to add for the probe to improve implementation results. This parameter applies to all probes.
Advanced Trigger
Check to enable the state machine-based trigger sequencing.