The API software is single threaded and uses one core for its processing.

Changes to the CAM database are made using the insert, update, or delete functions. The required processing for these operations increases with the fill level of the CAM database. The required processing increases with the CAM width but does not increase with CAM depth. The insert function is twice as fast as the update and delete functions.