Important: As discussed in Default Interfaces for Vitis Kernel Flow, the AXI4 adapter interfaces are the default interfaces used by Vitis HLS for the Vitis Application Acceleration Development flow.

The AXI4 interfaces supported by Vitis HLS include the AXI4-Stream interface (axis), AXI4-Lite (s_axilite), and AXI4 master (m_axi) interfaces. For a complete description of the AXI4 interfaces, including timing and ports, see the Vivado Design Suite: AXI Reference Guide (UG1037).

s_axilite
Specify this protocol on any type of argument except streams. The s_axilite mode specifies an AXI4-Lite slave interface.
Tip: You can bundle multiple arguments into a single s_axilite interface.
m_axi
Specify on arrays and pointers (and references in C++) only. The m_axi mode specifies an AXI4 Memory Mapped interface.
Tip: You can group bundle arguments into a single m_axi interface.
axis