In Zynq UltraScale+ MPSoCs, ECT is configured with four broadcast channels, nine CTIs, and a CTM. The table below shows the trigger input and trigger output connections of each CTI. These are hard-wired connections. For more details, refer to Zynq UltraScale+ Device Technical Reference Manual (UG1085).

Table 1. CTI Trigger Ports in Zynq UltraScale+ MPSoCs
CTI Trigger Port Signal
CTI 0 (soc_debug_fpd)
IN 0 ETF 1 FULL
IN 1 ETF 1 ACQCOMP
IN 2 ETF 2 FULL
IN 3 ETF 2 ACQCOMP
IN 4 ETR FULL
IN 5 ETR ACQCOMP
IN 6 -
IN 7 -
OUT 0 ETF 1 FLUSHIN
OUT 1 ETF 1 TRIGIN
OUT 2 ETF 2 FLUSHIN
OUT 3 ETF 2 TRIGIN
OUT 4 ETR FLUSHIN
OUT 5 ETR TRIGIN
OUT 6 TPIU FLUSHIN
OUT 7 TPIU TRIGIN
CTI 1 (soc_debug_fpd)
IN 0 FTM
IN 1 FTM
IN 2 FTM
IN 3 FTM
IN 4 STM TRIGOUTSPTE
IN 5 STM TRIGOUTSW
IN 6 STM TRIGOUTHETE
IN 7 STM ASYNCOUT
OUT 0 FTM
OUT 1 FTM
OUT 2 FTM
OUT 3 FTM
OUT 4 STM HWEVENTS
OUT 5 STM HWEVENTS
OUT 6 -
OUT 7 HALT SYSTEM TIMER
CTI 2 (soc_debug_fpd)
IN 0 ATM 0
IN 1 ATM 1
IN 2 -
IN 3 -
IN 4 -
IN 5 -
IN 6 -
IN 7 -
OUT 0 ATM 0
OUT 1 ATM 1
OUT 2 -
OUT 3 -
OUT 4 -
OUT 5 -
OUT 6 -
OUT 7 picture debug start
CTI 0, 1 (RPU)
IN 0 DBGTRIGGER
IN 1 PMUIRQ
IN 2 ETMEXTOUT[0]
IN 3 ETMEXTOUT[1]
IN 4 COMMRX
IN 5 COMMTX
IN 6 ETM TRIGGER
IN 7 -
OUT 0 EDBGRQ
OUT 1 ETMEXTIN[0]
OUT 2 ETMEXTIN[1]
OUT 3 -(CTIIRQ, not connected)
OUT 4 -
OUT 5 -
OUT 6 -
OUT 7 DBGRESTART
CTI 0, 1, 2, 3 (APU)
IN 0 DBGTRIGGER
IN 1 PMUIRQ
IN 2 -
IN 3 -
IN 4 ETMEXTOUT[0]
IN 5 ETMEXTOUT[1]
IN 6 ETMEXTOUT[2]
IN 7 ETMEXTOUT[3]
OUT 0 EDBGRQ
OUT 1 DBGRESTART
OUT 2 CTIIRQ
OUT 3 -
OUT 4 ETMEXTIN[0]
OUT 5 ETMEXTIN[1]
OUT 6 ETMEXTIN[2]
OUT 7 ETMEXTIN[3]