Grouping Blocks within a Clock Domain - 2022.1 English

Vitis Model Composer User Guide (UG1483)

Document ID
UG1483
Release Date
2022-05-26
Version
2022.1 English

Blocks are grouped together in Model Composer by using a Subsystem. Grouping blocks within a clock domain is no different except that a System Generator token has to be placed in the Subsystem you want to “mark” as a Clock Domain. This is shown in the following figure.

Figure 1. Source Clock Domain

In this figure, a clock domain Subsystem called src_domain has been created and a System Generator token added. Notice that the clocking tab of the System Generator token is selected. In this tab, the FPGA clock period has been set to (1000/368) ns (368 MHz) and the Simulink system period to 1. This implies that an advance of 1 Simulink second corresponds to (1000/368) ns of FPGA clock.

Similarly, another group of blocks representing another clock domain is included in a Subsystem called dest_domain, as shown in the figure below.

Figure 2. Destination Clock Domain

In this design, the dest_domain Subsystem is configured to run at an FPGA clock period of 1000/245 ns (245 MHz). The Simulink system period is set to 368/245. This is done because the Simulink system period of the src_domain Subsystem is set to 1. Hence, you normalize with the System period from the src_domain which is faster.