AXI4-Stream Interfaces - 5.1 English

MIPI CSI-2 Receiver Subsystem Product Guide (PG232)

Document ID
PG232
Release Date
2022-04-26
Version
5.1 English

If data is not being transmitted or received, check the following conditions:

If transmit <interface_name>_tready is stuck Low following the <interface_name>_tvalid input being asserted, the subsystem cannot send data.

If the receive <interface_name>_tvalid is stuck Low, the subsystem is not receiving data.

Check that the video_aclk and dphy_clk_200M inputs are connected and toggling.

Check subsystem configuration.

Ensure “Stream line buffer full” condition not getting reported in subsystem Interrupt Status register.

Sideband Information on AXI4-Stream Interfaces.

Sideband information such as frame and line number appear on the TUSER signal of the AXI4-Stream interface.

Start of fame, frame number, line number, word count, and data type need to be sampled by the user on the first beat of the transfer.

Note: Frame Number and Line number is an optional information set by the TX. According to the MIPI CSI-2 specification, TX can send a fixed "0" if these information is not used.

Packet Error, ECC, and CRC need to be sampled by the user on the last beat of the transfer.

Note: The side band information are optionally sent by the sensor. Please refer to the Low Level Protocol section of MIPI CSI-2 standard v2.0 [Ref 1] for more details.

Figure B-2: Sideband Information (TUSER) Timing Diagram
Fig_B-2.PNG