User Parameters - 3.0 English

AXI Ethernet Lite MAC LogiCORE IP Product Guide (PG135)

Document ID
PG135
Release Date
2021-11-02
Version
3.0 English

Table: GUI Parameter to User Parameter Relationship shows the relationship between the GUI fields in the Vivado IDE and the User Parameters (which can be viewed in the Tcl Console).

Table 4-1: GUI Parameter to User Parameter Relationship

GUI Parameter/Value (1)

User Parameter/Value (1)

Default Value (1)

AXI Protocol

C_S_AXI_PROTOCOL

AXI4LITE

AXI Clock Frequency (2)

AXI_ACLK_FREQ_MHZ

100

Communication Mode (3)

C_DUPLEX

1

Number of Transmit Buffers

C_TX_PING_PONG

1

Number of Receive Buffers

C_RX_PING_PONG

1

Enable Internal Loopback (4)

C_INCLUDE_INTERNAL_LOOPBACK

0

Enable Global Buffers for PHY Clocks

C_INCLUDE_GLOBAL_BUFFERS

1

Enable MII Management Module

C_INCLUDE_MDIO

1

ID Width (5)

C_S_AXI_ID_WIDTH

0

Notes:

1. Parameter values are listed in the table where the GUI parameter value differs from the user parameter value. Such values are shown in this table as indented below the associated parameter.

2. Clock frequency should be minimum four times of TX/RX clocks.

3. Value “0” for Half Duplex and Value “1” for Full Duplex.

4. Not applicable when Communication Mode is “0”(Half Duplex), and value should be “0.”

5. Applicable only when AXI Protocol is AXI4 (Full).