Power displays default calibration rail names, power (W), voltage (V), and
current (A). You can view all rail values simultaneously, or individually. During the
operation, the following status is indicated:
- A loader symbol is displayed under the Status column.
- On success, a green tick appears.
- On failure, a red color cross icon is displayed. Hover the mouse cursor on the red colored cross icon to see the error message.
Figure 1. Power/Use Default Calibration Page
In addition, four tabs at the top of the page provide the following features:
- Use Default Calibration gathers power information based on default INA226 calibration data. The default INA226 data can be obtained by selecting Get INA226 Registers after a power cycle.
- The default data can be changed using Set INA226 Registers.
- Use Custom Calibration reads power information based on the custom settings set with Set INA226 Registers.