Power

VCK190/VMK180 Board Evaluation and Management (BEAM) Tool User Guide (UG1573)

Document ID
UG1573
Release Date
2023-02-22
Revision
1.0 English
Power displays default calibration rail names, power (W), voltage (V), and current (A). You can view all rail values simultaneously, or individually. During the operation, the following status is indicated:
  • A loader symbol is displayed under the Status column.
  • On success, a green tick appears.
  • On failure, a red color cross icon is displayed. Hover the mouse cursor on the red colored cross icon to see the error message.
Figure 1. Power/Use Default Calibration Page
In addition, four tabs at the top of the page provide the following features:
  • Use Default Calibration gathers power information based on default INA226 calibration data. The default INA226 data can be obtained by selecting Get INA226 Registers after a power cycle.
  • The default data can be changed using Set INA226 Registers.
  • Use Custom Calibration reads power information based on the custom settings set with Set INA226 Registers.