Throughout this tutorial, you will use and reuse the same filter with complex coefficients. This filter has 32 coefficients (or taps) and no symmetry characteristics.

{   -82,  -253},{     0,  -204},{    11,   -35},{  -198,   273},
{  -642,   467},{ -1026,   333},{  -927,     0},{  -226,   -73},
{   643,   467},{   984,  1355},{   550,  1691},{     0,   647},
{   538, -1656},{  2860, -3936},{  6313, -4587},{  9113, -2961},
{  9582,     0},{  7421,  2411},{  3936,  2860},{  1023,  1409},
{  -200,  -615},{     0, -1778},{   517, -1592},{   467,  -643},
{  -192,   140},{  -882,   287},{ -1079,     0},{  -755,  -245},
{  -273,  -198},{    22,    30},{    63,   194},{     0,   266}

ImpulseResponse

The output of this filter will have a much higher amplitude than the input. A scaling factor of 2^15 should be applied to get back to the normalized data. On debugging phase, when only impulses are given to the filter, the scaling factor can be reduced to 1 so that we can verify that the output looks like the impulse response of the filter.