Clock Network Deskew Using the Deskew Phase Detector and Phase Interpolator

Versal Adaptive SoC Clocking Resources Architecture Manual (AM003)

Document ID
AM003
Release Date
2023-05-16
Revision
1.5 English

Similar to the MMCM, the DPLL can also deskew two CLKOUT networks chosen by the user. However, unlike the MMCM, only one pair of clocks can be deskewed using this method.

For the functional description, see the MMCMs section of this manual.