The SYSMON maintains a pair of registers for each enabled channel to store the maximum (SUPPLYXX_MAX) and minimum (SUPPLYXX_MIN) values sampled since the last reset. If a given channel has averaging enabled, the maximum and minimum registers only update with averaged noise-filtered readings, rather than the max/min for a single sample. With the STATUS_RESET register, individual supplies' maximum and minimum registers can be uniquely reset. These registers are described in the PMC_SYSMON_CSR module of the Versal Adaptive SoC Register Reference (AM012).