Maximum/Minimum Tracking

Versal ACAP System Monitor Architecture Manual (AM006)

Document ID
AM006
Release Date
2022-05-17
Revision
1.3 English

The SYSMON maintains a pair of registers for each enabled channel to store the maximum (SUPPLYXX_MAX) and minimum (SUPPLYXX_MIN) values sampled since the last reset. If a given channel has averaging enabled, the maximum and minimum registers only update with averaged noise-filtered readings, rather than the max/min for a single sample. With the STATUS_RESET register, individual supplies' maximum and minimum registers can be uniquely reset. These registers are described in the SYSMON _ROOT module of the Versal ACAP Register Reference (AM012).