Cross-Domain Clock Routing Consideration

Versal Adaptive SoC Technical Reference Manual (AM011)

Document ID
AM011
Release Date
2023-10-05
Revision
1.6 English

When using clocks from another power domain, consider power management software that can turn off a power domain.

Note: In the Vivado CIPS wizard, the auto-select mode restricts some clocks from being routed across a power domain. For example, the LPD and FPD divider clock outputs are not routed to the PMC power domain because power management software might turn off the FPD or both the LPD and FPD.

The power states are described in the Power chapter.