LPD I2C Loopback Connection

Versal ACAP Technical Reference Manual (AM011)

Document ID
AM011
Release Date
2022-12-16
Revision
1.5 English

The I/O signals of the two LPD I2C controllers are connected together when the [I2C0_LOOP_I2C1] bit is set = 1. In this mode, the serial clocks are connected together and the serial data signals are connected together.