Transmit FIFO Fill

Versal ACAP Technical Reference Manual (AM011)

Document ID
AM011
Release Date
2022-12-16
Revision
1.5 English
Table 1. I2C Transmit FIFO Fill
Task Register Register Field Bits Operation
Read transfer size register Transfer_Size, 0x14 Transfer_Size 7:0 Read operation
Calculate available bytes = FIFO DEPTH(16) – Transfer_Size.
Fill data register with the data until available bytes count is reached. See Send Byte.