CFRM_IDR (CFRAME_REG) Register Description
Register Name | CFRM_IDR |
---|---|
Relative Address | 0x0000000180 |
Absolute Address |
0x00F12D0180 (CFRAME00_REG) 0x00F12D2180 (CFRAME01_REG) 0x00F12D4180 (CFRAME02_REG) 0x00F12D6180 (CFRAME03_REG) 0x00F12D8180 (CFRAME04_REG) 0x00F12DA180 (CFRAME05_REG) 0x00F12DC180 (CFRAME06_REG) 0x00F12DE180 (CFRAME07_REG) 0x00F12E0180 (CFRAME08_REG) 0x00F12E2180 (CFRAME09_REG) 0x00F12E4180 (CFRAME10_REG) 0x00F12E6180 (CFRAME11_REG) 0x00F12E8180 (CFRAME12_REG) 0x00F12EA180 (CFRAME13_REG) 0x00F12EC180 (CFRAME14_REG) 0x00F12EE180 (CFRAME_BCAST_REG) |
Width | 128 |
Type | woWrite-only |
Reset Value | 0x00000000 |
Description | Interrupt Disable Register. A write of to this location will mask the interrupt. (IMR = 1) |
CFRM_IDR (CFRAME_REG) Register Bit-Field Summary
Field Name | Bits | Type | Reset Value | Description |
---|---|---|---|---|
Reserved | 127:22 | woWrite-only | 0x0 | reserved |
READ_BROADCAST_ERROR | 21 | woWrite-only | 0x0 | IDR for read with broadcast address |
CMD_MISSING_ERROR | 20 | woWrite-only | 0x0 | IDR for write/read without WCFG/RCFG |
RW_ROWOFF_ERROR | 19 | woWrite-only | 0x0 | IDR for CRAM read/write when row is off |
READ_REG_ADDR_ERROR | 18 | woWrite-only | 0x0 | IDR for read register address error |
READ_BLK_TYPE_ERROR | 17 | woWrite-only | 0x0 | IDR for read block type error |
READ_FRAME_ADDR_ERROR | 16 | woWrite-only | 0x0 | IDR for read frame address error |
WRITE_REG_ADDR_ERROR | 15 | woWrite-only | 0x0 | IDR for write register address error |
Reserved | 14 | woWrite-only | 0x0 | Reserved |
WRITE_BLK_TYPE_ERROR | 13 | woWrite-only | 0x0 | IDR for write block type error |
WRITE_FRAME_ADDR_ERROR | 12 | woWrite-only | 0x0 | IDR for write frame address error |
MFW_OVERRUN_ERROR | 11 | woWrite-only | 0x0 | IDR for MFW overrun error |
FAR_FIFO_UNDERFLOW | 10 | woWrite-only | 0x0 | IDR for FAR Fifo Underflow |
FAR_FIFO_OVERFLOW | 9 | woWrite-only | 0x0 | IDR for FAR Fifo Overflow |
PER_FRAME_SEQ_ERROR | 8 | woWrite-only | 0x0 | IDR for Per frame CRC has a sequence error |
CRC_ERROR | 7 | woWrite-only | 0x0 | IDR for CRC Error during configuration / partial reconfiguration |
WRITE_OVERRUN_ERROR | 6 | woWrite-only | 0x0 | IDR for Write CFI Bandwidth is faster than CRAM bandwidth |
READ_OVERRUN_ERROR | 5 | woWrite-only | 0x0 | IDR for Read overrun |
CMD_INTERRUPT_ERROR | 4 | woWrite-only | 0x0 | IDR for CMD interrupted |
WRITE_INTERRUPT_ERROR | 3 | woWrite-only | 0x0 | IDR for CRAM Write transaction interrupted |
READ_INTERRUPT_ERROR | 2 | woWrite-only | 0x0 | IDR for CRAM Read transaction interrupted |
SEU_CRC_ERROR | 1 | woWrite-only | 0x0 | IDR for SEU CRC Error |
SEU_ECC_ERROR | 0 | woWrite-only | 0x0 | IDR for SEU ECC Error |