RxBuff1_DW12_Msg_n (CANFD) Register

Versal Adaptive SoC Register Reference (AM012)

Document ID
AM012
Release Date
2023-08-29
Revision
1.3

RxBuff1_DW12_Msg_n (CANFD) Register Description

Register NameRxBuff1_DW12_Msg_n
Relative Address0x0000004138
Absolute Address 0x00FF064138 (CANFD0)
0x00FF074138 (CANFD1)
Width32
TyperoRead-only
Reset Value0x00000000
Description64 dw_12 regs for RxBuffer_1 msgs 0 to 63 at 0x4138, 0x4180, etc (0x48 step)

For CANFD frames, DW 12 includes data bytes 48, 49, 50, 51. (DW 12 not used for CAN) Note: First DW 12 register is at offset 0x4138. Second DW 12 register is at 0x4180; the address stepping is 0x048. Software Driver name: RF1_RB_DW12 Original Bit Field Engineering Name: Data_bytes44

RxBuff1_DW12_Msg_n (CANFD) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
DB4831:24roRead-only0Data Byte 48
Software Driver name: DB48
Note: Field name reference: Data_bytes48
DB4923:16roRead-only0Data Byte 49
Software Driver name: DB49
Note: Field name reference: Data_bytes49
DB5015:8roRead-only0Data Byte 50
Software Driver name: DB50
Note: Field name reference: Data_bytes50
DB51 7:0roRead-only0Data Byte 51
Software Driver name: DB51
Note: Field name reference: Data_bytes51