por_dn_pmu_event_sel_u_hnd_nid8 (CPM4_CMN600) Register

Versal Adaptive SoC Register Reference (AM012)

Document ID
AM012
Release Date
2023-08-29
Revision
1.3

por_dn_pmu_event_sel_u_hnd_nid8 (CPM4_CMN600) Register Description

Register Namepor_dn_pmu_event_sel_u_hnd_nid8
Relative Address0x0000122000
Absolute Address 0x00FC122000 (CPM4_CMN)
Width64
TypemixedMixed types. See bit-field details.
Reset Value0x00000000
DescriptionSpecifies the PMU event to be counted.

por_dn_pmu_event_sel_u_hnd_nid8 (CPM4_CMN600) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
Reserved63:36razRead as zero0x0reserved
pmu_occup1_id35:32rwNormal read/write0x0PMU occupancy event selector ID 4b0000: All 4b0001: DVM ops 4b0010: DVM syncs
Reserved31:30razRead as zero0x0reserved
pmu_event3_id29:24rwNormal read/write0x0PMU Event 3 ID; see pmu_event0_id for encodings
Reserved23:22razRead as zero0x0reserved
pmu_event2_id21:16rwNormal read/write0x0PMU Event 2 ID; see pmu_event0_id for encodings
Reserved15:14razRead as zero0x0reserved
pmu_event1_id13:8rwNormal read/write0x0PMU Event 1 ID; see pmu_event0_id for encodings
Reserved 7:6razRead as zero0x0reserved
pmu_event0_id 5:0rwNormal read/write0x0PMU Event 0 ID 6h00: No event 6h01: Number of TLBI DVM op requests 6h02: Number of BPI DVM op requests 6h03: Number of PICI DVM op requests 6h04: Number of VICI DVM op requests 6h05: Number of DVM sync requests 6h06: Number of DVM op requests that were filtered using VMID filtering 6h07: Number of DVM op requests to RNDs, BPI or PICI/VICI, that were filtered 6h08: Number of retried REQ 6h09: Number of SNPs sent to RNs 6h0a: Number of SNPs stalled to RNs due to lack of Crds 6h0b: DVM tracker full counter 6h0c: DVM tracker occupancy counter