The following tables provide the required airflow
rate and airflow speed to X3522 NICs under
various operating conditions for 35W total card power. This is indicative of
requirements for the X3522 low latency
network adapter with hybrid mode disabled (its initial supplied state).
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (56.51 mm x 20.33 mm) at Sea Level for 35W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 1.4 | 110 | 0.08 | 1.4 | 120 | 0.09 |
30 | 1.6 | 130 | 0.10 | 1.7 | 140 | 0.11 |
35 | 2.0 | 160 | 0.12 | 2.1 | 170 | 0.13 |
40 | 2.5 | 210 | 0.17 | 2.6 | 220 | 0.18 |
45 | 3.3 | 270 | 0.24 | 3.5 | 290 | 0.26 |
50 | 4.6 | 380 | 0.38 | 4.9 | 400 | 0.41 |
55 | 7.3 | 600 | 0.74 | 7.7 | 630 | 0.80 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (56.51 mm x 20.33 mm) at 1200m Above Sea Level for 35W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 1.4 | 120 | 0.09 | 1.5 | 130 | 0.09 |
30 | 1.7 | 140 | 0.11 | 1.8 | 150 | 0.12 |
35 | 2.1 | 180 | 0.14 | 2.2 | 190 | 0.15 |
40 | 2.7 | 220 | 0.18 | 2.8 | 230 | 0.20 |
45 | 3.5 | 290 | 0.26 | 3.7 | 310 | 0.28 |
50 | 5.0 | 410 | 0.42 | 5.3 | 430 | 0.46 |
55 | 7.9 | 640 | 0.84 | 8.3 | 680 | 0.90 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (66.87 mm x 13.18 mm) at Sea Level for 35W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 0.7 | 70 | 0.04 | 0.8 | 80 | 0.04 |
30 | 0.8 | 80 | 0.04 | 0.9 | 90 | 0.04 |
35 | 0.9 | 100 | 0.05 | 1.0 | 110 | 0.05 |
40 | 1.0 | 110 | 0.07 | 1.1 | 130 | 0.06 |
45 | 1.2 | 130 | 0.09 | 1.4 | 150 | 0.08 |
50 | 1.5 | 160 | 0.12 | 1.6 | 180 | 0.10 |
55 | 1.6 | 180 | 0.14 | 1.8 | 190 | 0.11 |
60 | 2.1 | 220 | 0.20 | 2.2 | 240 | 0.16 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (66.87 mm x 13.18 mm) at 1200m Above Sea Level for 35W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 0.7 | 80 | 0.04 | 0.8 | 90 | 0.04 |
30 | 0.8 | 90 | 0.05 | 0.9 | 100 | 0.05 |
35 | 0.9 | 100 | 0.06 | 1.1 | 120 | 0.06 |
40 | 1.1 | 120 | 0.08 | 1.2 | 130 | 0.07 |
45 | 1.3 | 140 | 0.10 | 1.5 | 160 | 0.09 |
50 | 1.6 | 180 | 0.13 | 1.8 | 190 | 0.11 |
55 | 1.8 | 190 | 0.15 | 1.9 | 210 | 0.13 |
60 | 2.2 | 240 | 0.22 | 2.4 | 260 | 0.18 |
|
The following tables provide the required airflow
rate and airflow speed to X3522 NICs under
various operating conditions for 70W total card power. This is indicative of
requirements for the X3522 low latency
network adapter with hybrid mode enabled to make it programmable, and the X3522PV adaptable accelerator card.
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (56.51 mm x 20.33 mm) at Sea Level for 70W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 3.6 | 300 | 0.27 | 3.8 | 310 | 0.29 |
30 | 4.3 | 350 | 0.34 | 4.5 | 370 | 0.37 |
35 | 5.2 | 430 | 0.45 | 5.5 | 450 | 0.49 |
40 | 6.6 | 540 | 0.64 | 6.9 | 570 | 0.68 |
45 | 8.7 | 710 | 0.97 | 9.1 | 740 | 1.04 |
50 | 12.3 | 1000 | 1.69 | 12.8 | 1040 | 1.81 |
55 | 19.5 | 1580 | 3.67 | 20.2 | 1640 | 3.92 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (56.51 mm x 20.33 mm) at 1200m Above Sea Level for 70W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 3.9 | 320 | 0.30 | 4.1 | 330 | 0.32 |
30 | 4.6 | 380 | 0.38 | 4.9 | 400 | 0.41 |
35 | 5.6 | 460 | 0.50 | 5.9 | 480 | 0.54 |
40 | 7.1 | 580 | 0.71 | 7.5 | 610 | 0.76 |
45 | 9.4 | 760 | 1.09 | 9.8 | 800 | 1.17 |
50 | 13.3 | 1080 | 1.91 | 13.8 | 1120 | 2.05 |
55 | 21.1 | 1710 | 4.20 | 21.8 | 1770 | 4.48 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (66.87 mm x 13.18 mm) at Sea Level for 70W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 2.6 | 280 | 0.29 | 2.8 | 300 | 0.22 |
30 | 3.0 | 330 | 0.37 | 3.2 | 340 | 0.27 |
35 | 3.5 | 380 | 0.47 | 3.7 | 390 | 0.34 |
40 | 4.2 | 440 | 0.62 | 4.3 | 450 | 0.43 |
45 | 5.0 | 530 | 0.85 | 5.0 | 540 | 0.57 |
50 | 6.1 | 640 | 1.22 | 6.1 | 640 | 0.78 |
55 | 6.6 | 700 | 1.42 | 6.6 | 700 | 0.89 |
60 | 8.3 | 880 | 2.19 | 8.2 | 870 | 1.31 |
|
Inlet Temperature vs Airflow Requirement of PCIe Card Slot (66.87 mm x 13.18 mm) at 1200m Above Sea Level for 70W Total Card Power | ||||||
---|---|---|---|---|---|---|
Inlet Temperature to the Card (°C) | With SFP28 (75°C) | Without SFP28 1 | ||||
CFM | LFM | Static Pressure | CFM | LFM | Static Pressure | |
25 | 2.8 | 300 | 0.33 | 3.0 | 320 | 0.25 |
30 | 3.3 | 350 | 0.41 | 3.4 | 360 | 0.30 |
35 | 3.8 | 400 | 0.53 | 3.9 | 420 | 0.38 |
40 | 4.5 | 480 | 0.71 | 4.6 | 490 | 0.49 |
45 | 5.3 | 570 | 0.97 | 5.4 | 580 | 0.64 |
50 | 6.5 | 690 | 1.40 | 6.5 | 690 | 0.88 |
55 | 7.1 | 760 | 1.64 | 7.1 | 750 | 1.02 |
60 | 9.0 | 960 | 2.53 | 8.8 | 940 | 1.50 |
|