Absolute Maximum Ratings

Versal Prime Series Data Sheet: DC and AC Switching Characteristics (DS956)

Document ID
DS956
Release Date
2022-08-02
Revision
1.5 English
Table 1. Absolute Maximum Ratings—Power, Voltages, and Current
Symbol Description 1 Min Max Units
VCCAUX Programmable logic auxiliary power supply –0.500 1.650 V
VCCAUX_PMC Platform management controller (PMC) auxiliary power supply voltage –0.500 1.650 V
VCCAUX_SMON 2 PMC system monitor power supply relative to GND_SMON –0.500 1.650 V
VCC_BATT Battery power supply –0.500 1.650 V
VCC_FUSE eFUSE programming power supply –0.500 2.000 V
VCCINT Programmable logic primary power supply –0.500 0.970 V
VCC_CPM5 CPM5 primary power supply –0.500 0.970 V
VCC_IO 3 XPIO power supply –0.500 0.970 V
VCCO 4

XPIO bank 7## and bank 8## output driver power supply

Where the bank number is the three-digit bank number beginning with 7 or 8

–0.500 1.650 V

HDIO bank 3## and bank 4## output driver power supply

Where the bank number is the three-digit bank number beginning with 3 or 4

–0.500 3.63 V

PSIO bank 5## power supplies

Where the bank number is the three-digit bank number beginning with 5

–0.500 3.63 V
VCC_PMC PMC primary power supply –0.500 0.970 V
VCC_PSFP PS full-power domain power supply –0.500 0.970 V
VCC_PSLP PS low-power domain power supply –0.500 0.970 V
VCC_RAM PL RAM and clocking network power supply –0.500 0.970 V
VCC_SOC 3 Network on Chip (NoC) and DDR memory controller power supply –0.500 0.970 V
VIN 4, 5 I/O input voltage for PSIO, HDIO, and XPIO banks –0.550 VCCO + 0.550 V
VREF PMC system monitor reference input (VREFP/VREFN) relative to GND_SMON –0.500 1.120 V
GTY and GTYP (or GTM) Transceivers

VGTY_AVCC

VGTM_AVCC

GTY and GTYP (or GTM) transceiver primary analog power supply 6

–0.500 0.97 V

VGTY_AVCCAUX

VGTM_AVCCAUX

GTY and GTYP (or GTM) transceiver auxiliary analog (PLL) power supply 6

–0.500 1.650 V

VGTY_AVTT

VGTM_AVTT

GTY and GTYP (or GTM) transceiver termination power supply 6

–0.500 1.320 V

VGTY_AVTTRCAL

VGTM_AVTTRCAL

GTY and GTYP (or GTM) transceiver analog resistor calibration power supply 6

–0.500 1.320 V
VCCINT_GT Digital supply voltage for select modules in the GTM transceivers –0.500 0.97 V
VGTY_REFCLK_DC

VGTM_REFCLK_DC

Transceiver reference clock absolute input DC voltage –0.500 1.000 V
VGTY_REFCLK_AC

VGTM_REFCLK_AC

Transceiver reference clock absolute input AC voltage 7 –0.500 1.200 V
VIN_DC Receiver (RXP/RXN) and transmitter (TXP/TXN) absolute DC voltage Unpowered –0.800 0.800 V
Powered –0.300 1.000 V
VIN_AC+DC Receiver (RXP/RXN) and transmitter (TXP/TXN) absolute AC plus DC voltage Unpowered –0.800 0.800 V
Powered –0.500 1.250 V
IDCIN_FLOAT DC input current for receiver input pins DC coupled RX termination = floating 8 10 mA
IDCIN_GTY_AVTT DC input current for GTY and GTYP receiver input pins DC coupled RX termination = VGTY_AVTT 16 mA
IDCIN_GTM_AVTT DC input current for GTM receiver input pins DC coupled RX termination = VGTM_AVTT 12 mA
IDCIN_GTY_GND DC input current for GTY and GTYP receiver input pins DC coupled RX termination = GND 16 mA
IDCIN_GTM_GND DC input current for GTM receiver input pins DC coupled RX termination = GND 12 mA
IDCIN_PROG DC input current for receiver input pins DC coupled RX termination = programmable 9 0 mA
IDCOUT_FLOAT DC output current for transmitter pins DC coupled RX termination = floating 6 mA
IDCOUT_GTY_AVTT DC output current for transmitter pins DC coupled RX termination = VGTY_AVTT 6 mA
Other Ratings
IDC Available output current at the pad –20 20 mA
IRMS Available RMS output current at the pad –20 20 mA
  1. Stresses beyond those listed under Absolute Maximum Ratings might cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions is not implied. Exposure to Absolute Maximum Ratings conditions for extended periods of time might affect device reliability.
  2. VCCAUX_SMON must be connected to VCCAUX_PMC . See Versal ACAP System Monitor Architecture Manual (AM006) for VCCAUX_SMON information and filter considerations.
  3. VCC_IO must be connected to VCC_SOC.
  4. When operating outside of the recommended operating conditions, refer to Table 1 and Table 2 for maximum overshoot and undershoot specifications.
  5. The lower absolute voltage specification always applies.
  6. For more information on supported GTY and GTYP (or GTM) transceiver terminations see the Versal ACAP GTY and GTYP Transceivers Architecture Manual (AM002) or Versal ACAP GTM Transceivers Architecture Manual (AM017) .
  7. GTY_REFCLK AC signal operates in the reference clock frequency range. See GTY and GTYP Transceiver Reference Clock Switching Characteristics.
  8. AC coupled operation is not supported for RX termination = floating.
  9. DC coupled operation is not supported for RX termination = programmable.
Table 2. Absolute Maximum Ratings—Temperature
Symbol Description 1 Min Max Units
TSTG Storage temperature (ambient, unpowered) –55 125 °C
TSOL 2 Maximum dry rework soldering temperature 260 °C
Tj Maximum junction temperature 125 °C
  1. Stresses beyond those listed under Absolute Maximum Ratings might cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions is not implied. Exposure to Absolute Maximum Ratings conditions for extended periods of time might affect device reliability.
  2. For soldering guidelines and thermal considerations, see the Versal ACAP Packaging and Pinouts Architecture Manual (AM013).