Table 1. Absolute Maximum Ratings—Power, Voltages, and Current
Symbol Description 1 Min Max Units
VCCAUX Programmable logic auxiliary power supply –0.500 1.650 V
VCCAUX_PMC Platform management controller (PMC) auxiliary power supply voltage –0.500 1.650 V
VCCAUX_SMON 2 PMC system monitor power supply relative to GND_SMON –0.500 1.650 V
VCC_BATT Battery power supply –0.500 1.650 V
VCC_FUSE eFUSE programming power supply –0.500 2.000 V
VCCINT Programmable logic primary power supply –0.500 0.970 V
VCC_CPM5 CPM5 primary power supply –0.500 0.970 V
VCC_IO 3 XPIO power supply –0.500 0.970 V
VCCO 4

XPIO bank 7## output driver power supply

Where the bank number is the three-digit bank number beginning with 7

–0.500 1.650 V

HDIO bank 3## and bank 4## output driver power supply

Where the bank number is the three-digit bank number beginning with 3 or 4

–0.500 3.63 V

PSIO bank 5## power supplies

Where the bank number is the three-digit bank number beginning with 5

–0.500 3.63 V
VCC_PMC PMC primary power supply –0.500 0.970 V
VCC_PSFP PS full-power domain power supply –0.500 0.970 V
VCC_PSLP PS low-power domain power supply –0.500 0.970 V
VCC_RAM PL RAM and clocking network power supply –0.500 0.970 V
VCC_SOC 3 Network on Chip (NoC) , DDR memory controller, and video decoder unit (VDU) power supply –0.500 0.970 V
VIN 4, 5 I/O input voltage for PSIO, HDIO, and XPIO banks –0.550 VCCO + 0.550 V
VREF PMC system monitor reference input (VREFP/VREFN) relative to GND_SMON –0.500 1.120 V
GTY and GTYP Transceivers

VGTY_AVCC

VGTYP_AVCC

GTY and GTYP transceiver primary analog power supply 6

–0.500 0.97 V

VGTY_AVCCAUX

VGTYP_AVCCAUX

GTY and GTYP transceiver auxiliary analog (PLL) power supply 6

–0.500 1.650 V

VGTY_AVTT

VGTYP_AVTT

GTY and GTYP transceiver termination power supply 6

–0.500 1.320 V

VGTY_AVTTRCAL

VGTYP_AVTTRCAL

GTY and GTYP transceiver analog resistor calibration power supply 6

–0.500 1.320 V

VGTY_REFCLK_DC

VGTYP_REFCLK_DC

Transceiver reference clock absolute input DC voltage –0.500 1.000 V

VGTY_REFCLK_AC

VGTYP_REFCLK_AC

Transceiver reference clock absolute input AC voltage 7 –0.500 1.350 V
VIN_DC Receiver (RXP/RXN) and transmitter (TXP/TXN) absolute DC voltage Unpowered –0.800 0.800 V
Powered –0.300 1.000 V
VIN_AC+DC Receiver (RXP/RXN) and transmitter (TXP/TXN) absolute AC plus DC voltage Unpowered –0.800 0.800 V
Powered –0.500 1.250 V
IDCIN_FLOAT DC input current for receiver input pins DC coupled RX termination = floating 8 10 mA

IDCIN_GTY_AVTT

IDCIN_GTYP_AVTT

DC input current for GTY and GTYP receiver input pins DC coupled RX termination = VGTY_AVTT or VGTYP_AVTT 16 mA

IDCIN_GTY_GND

IDCIN_GTYP_GND

DC input current for GTY and GTYP receiver input pins DC coupled RX termination = GND 10 16 mA
IDCIN_PROG DC input current for receiver input pins DC coupled RX termination = programmable 9 0 mA
IDCOUT_FLOAT DC output current for transmitter pins DC coupled RX termination = floating 6 mA

IDCOUT_GTY_AVTT

IDCOUT_GTYP_AVTT

DC output current for transmitter pins DC coupled RX termination = VGTY_AVTT or VGTYP_AVTT 6 mA
Other Ratings
IDC Available output current at the pad –20 20 mA
IRMS Available RMS output current at the pad –20 20 mA
  1. Stresses beyond those listed under Absolute Maximum Ratings might cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions is not implied. Exposure to Absolute Maximum Ratings conditions for extended periods of time might affect device reliability.
  2. VCCAUX_SMON must be connected to VCCAUX_PMC . See Versal Adaptive SoC System Monitor Architecture Manual (AM006) for VCCAUX_SMON information and filter considerations.
  3. VCC_IO must be connected to VCC_SOC.
  4. When operating outside of the recommended operating conditions, refer to the specifications in the VIN Maximum Allowed AC Voltage Overshoot and Undershoot section.
  5. The lower absolute voltage specification always applies.
  6. For more information on supported GTY and GTYP transceiver terminations see the Versal Adaptive SoC GTY and GTYP Transceivers Architecture Manual (AM002) .
  7. The GTY_REFCLK AC or GTYP_REFCLK AC signal operates in the reference clock frequency range. See GTY and GTYP Transceiver Reference Clock Switching Characteristics.
  8. AC coupled operation is not supported for RX termination = floating.
  9. DC coupled operation is not supported for RX termination = programmable.
  10. For DC coupled links with RX termination set to ground, the transmitter or the board should insure that the RX input common mode voltage is set between 0.2V and 0.8V.
Table 2. Absolute Maximum Ratings—Temperature
Symbol Description 1 Min Max Units
TSTG Storage temperature (ambient, unpowered) –55 125 °C
TSOL 2 Maximum dry rework soldering temperature 260 °C
Tj Maximum junction temperature 125 °C
  1. Stresses beyond those listed under Absolute Maximum Ratings might cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions is not implied. Exposure to Absolute Maximum Ratings conditions for extended periods of time might affect device reliability.
  2. For soldering guidelines and thermal considerations, see the Versal Adaptive SoC Packaging and Pinouts Architecture Manual (AM013).