Package Parameter Guidelines

Versal Premium Series Data Sheet: DC and AC Switching Characteristics (DS959)

Document ID
DS959
Release Date
2024-02-29
Revision
1.5 English

The parameters in this section provide the necessary values for calculating timing budgets for clock transmitter and receiver data-valid windows.

Table 1. Package Skew
Symbol Description Device Package Value Units
PKGSKEW Package Skew 1, 2 XCVP1002 NFVI1369 122 ps
VFVF1760 88 ps
XCVP1052 NFVI1369 122 ps
SBVJ1369 173 ps
VFVF1760 88 ps
XCVP1102 VFVF1760 83 ps
VSVA2785 134 ps
XCVP1202 VSVA2785 227 ps
XQVP1202 VSRC2197   ps
VSRA2785 227 ps
XCVP1402 VFVF1760 85 ps
VSVD2197 51 ps
VSVA2785 134 ps
VSVA3340 149 ps
XQVP1402 VSRF1760   ps
VSRA2785 134 ps
XCVP1502 VSVA2785 286 ps
VSVA3340 102 ps
XQVP1502 VSRA2785 286 ps
VSRA3340 102 ps
XCVP1552 VSVA2785 254 ps
VSVA3340 106 ps
XCVP1702 VSVA3340 101 ps
VSVA5601 179 ps
XCVP1802 LSVC4072 221 ps
VSVA5601 151 ps
XCVP1902 VSVA6865   ps
VSVB6865   ps
XCVP2502 VSVB3340 114 ps
VSVA5601 177 ps
XCVP2802 VSVA5601 174 ps
  1. These values represent the worst-case skew between any two SelectIO resources in the package: shortest delay to longest delay from die pad to ball.
  2. Package delay information is available for these device/package combinations. This information can be used to deskew the package.