PS Trace Interface

Versal HBM Series Data Sheet: DC and AC Switching Characteristics (DS960)

Document ID
DS960
Release Date
2024-02-29
Revision
1.4 English
Table 1. Trace Interface
Symbol Description 1 Performance as a Function of Speed Grade and Operating Voltage (VCC_PSFP) Units
0.88V (H) 0.80V (M) 0.70V (L)
-3 -2 -1 -2 -1
Min Max Min Max Min Max Min Max Min Max
FTCECLK Trace clock frequency (MIO) 200 200 200 200 167 MHz
Trace clock frequency (EMIO) 400 350 350 300 250 MHz
FDBGTCECLK Trace debug (DBG_TRACE) clock frequency 400 400 400 400 333 MHz
TTCECKO Trace clock to output delay, all outputs –0.5 0.5 –0.5 0.5 –0.5 0.5 –0.5 0.5 –0.5 0.5 ns
TTCECKO Trace clock duty cycle 45 55 45 55 45 55 45 55 45 55 %
  1. The test conditions are configured to the LVCMOS 3.3V I/O standard with a 12 mA drive strength, fast slew rate, and a 15 pF load.