VCC_SOM
|
Primary supply voltage for the SOM |
–0.500 |
6.000 |
V |
VCCO
|
Output drivers supply voltage for HD I/O banks (HDA, HDB,
HDC) |
–0.500 |
3.400 |
V |
Output drivers supply voltage for HP I/O banks (HPA, HPB,
HPC) |
–0.500 |
2.000 |
V |
VIN
3,
4
|
I/O input voltage for HD I/O banks |
–0.550 |
VCCO + 0.550 |
V |
I/O input voltage for HP I/O banks |
–0.550 |
VCCO + 0.550 |
V |
I/O input voltage for MIO (PS I/O) |
–0.550 |
2.350 |
V |
VCC_BATT
|
PS battery-backed RAM and battery-backed real-time clock (RTC) supply
voltage |
–0.500 |
2.000 |
V |
GTH Transceivers
5, 6
|
VMGTREFCLK
|
Transceiver reference clock absolute input
voltage |
–0.500 |
1.300 |
V |
VIN
|
Receiver (RXP/RXN) and transmitter (TXP/TXN)
absolute input voltage |
–0.500 |
1.200 |
V |
Temperature
7
|
TSTG
|
Storage temperature (ambient) |
–40 |
75 |
°C |
- Stresses beyond those
listed under Absolute Maximum Ratings might cause permanent
damage to the device. These are stress ratings only, and
functional operation of the device at these or any other
conditions beyond those listed under Operating Conditions is
not implied. Exposure to Absolute Maximum Ratings conditions
for extended periods of time might affect device
reliability.
- For more information
on absolute ratings see
Zynq
UltraScale+ MPSoC Data Sheet: DC and AC Switching
Characteristics (DS925).
- The lower absolute
voltage specification always applies.
- For I/O operation,
see the
UltraScale
Architecture SelectIO Resources User Guide (UG571).
- For more information on supported GTH
transceiver terminations see the
UltraScale
Architecture GTH Transceivers User Guide (UG576).
- DC coupled operation
is not supported for RX termination = programmable.
- For thermal considerations, see the
Kria K26 SOM
Thermal Design Guide (UG1090) and the Power Design Manager (PDM) tool (download at www.xilinx.com/power).
|