The following table captures a summary of the reliability testing completed on the K26 SOM. All reliability testing was done with the production SOM assembly inclusive of the circuit card assembly and aluminum heat spreader. For the full K26 SOM reliability and qualification report request access to the Kria SOM Qualification Report Lounge .

Table 1. Reliability Testing
Reliability Test K26C SOM (Commercial) K26I SOM (Industrial)
Temperature cycling JESD22-A104, Condition J (0°C to 100°C) JESD22-A104, Condition T (–40°C to 100°C)
Power cycling Ta = 50°C, RH = 80%; 55 min ON, 5 min OFF Ta = 50°C, RH = 80%; 55 min ON, 5 min OFF
Strife power cycling Power cycling, 0°C; 1 min ON, 1 min OFF Power cycling, –40°C; 1 min ON, 1 min OFF
Temperature and humidity Ta = 85°C, RH = 85% Ta = 85°C, RH = 85%
Mechanical vibration IEC 60068-2-64, 1.9 Grms IEC 60068-2-64, 5.04 Grms
Mechanical shock IEC 60068-2-27, 40 G IEC 60068-2-27, 100 G
Connector insertion life Room temperature, all the following connectors: dual 240-pin connectors. Room temperature, all the following connectors: dual 240-pin connectors.