Table 2-1: Port Name I/O Width Description

Signal Name

Direction

Width

Description

aclk

Input

1

AXI4-Stream ACLK.

aclken

Input

1

AXI4-Stream ACLKEN. Active-High.

aresetn

Input

1

AXI4-Stream ARESETN. Active-Low. Synchronous to ACLK.

axis_enable

Input

1

This input should be connected to the VTC detector locked status and is synchronous to vid_io_in_clk.

1 = Enable writes into FIFO

0 = Disable writes into FIFO

fid

Output

1

Field-ID for AXI4-Stream bus. Used only for interlaced video: 0=even field, 1=odd field. This bit changes coincident with SOF on the AXI4-Stream bus. It should be connected to the field-ID bit of the next device downstream that is field-aware, otherwise it should be left unconnected. Synchronous to aclk.

vid_io_in_clk

Input

1

Native video clock. Only available in independent clock mode.

vid_io_in_ce

Input

1

Native video clock enable

vid_io_in_reset

Input

1

Native video clock domain reset. Synchronous to vid_io_in_clk. Only available in independent clock mode. Active-High.

overflow

Output

1

Flag indicating that the FIFO has over-flowed. Synchronous to vid_io_in_clk. If an overflow occurs, this could indicate that the connected AXI4-Stream Slave is creating excessive back-pressure.

underflow

Output

1

Flag indicating that the FIFO has under-flowed. This should never occur under normal operation. Synchronous to aclk.