1000BASE-X or 2500BASE-X Standard without Optional Auto-Negotiation - 16.2 English

1G/2.5G Ethernet PCS/PMA or SGMII LogiCORE IP Product Guide (PG047)

Document ID
PG047
Release Date
2023-11-01
Version
16.2 English
It is not in the scope of this document to fully describe the 1000BASE-X PCS registers. See clauses 22 and 37 of the IEEE 802.3-2008 specification for further information.

Registers at undefined addresses are read-only and return 0s. The core can be reset three ways: reset, DCM_LOCKED and soft reset. All of these methods reset all the registers to the default values. For 2500BASE-X the register definition is same as 1000BASE-X.

Table 1. MDIO Registers for 1000BASE-X without Auto-Negotiation
Register Address Register Name
0 Register 0: Control Register
1 Register 1: Status Register
2,3 Registers 2 and 3: PHY Identifiers
15 Register 15: Extended Status