Enable Data FIFO - 2.1 English

AXI Interconnect LogiCORE IP Product Guide (PG059)

Document ID
PG059
Release Date
2022-05-17
Version
2.1 English

Description: Insert AXI Data FIFO on MI

°If parameter value is 0, no data FIFO is inserted.

°If parameter value is 1, a 32-deep data FIFO is inserted.

°If parameter value is 2, a 512-deep data FIFO is inserted and its packet mode feature is enabled.

Format/Range: Integer (0, 1, 2)

Default Value: 0