•Translation Mode
This parameter is used only when translating from AXI4 to AXI3 or from AXI4 or AXI3 to AXI4LITE.
°Description:
°0 = Unprotected: Master must be well-behaved. For conversion to AXI4LITE, all transactions received on the SI must be single-beat transfers (AWLEN or ARLEN = 0). For conversion from AXI4 to AXI3, all bursts received on the SI must be <= 16 beats (AWLEN or ARLEN <= 15).
°2 = Conversion: Incompatible bursts split into multiple transactions (AXI4-to-AXI3 only)
°Format/Range: Integer (0, 2)
°Default Value: 2