After the pma_init signal is deasserted, both tx_reset_pb and rx_reset_pb can be deasserted at the same time. For proper functioning of the link, it is recommended that the data transmission must begin only after partner rx_channel_up is seen to avoid loss of data.

Figure 3-6: Aurora 64B/66B Simplex TX and RX Power On Sequence

X-Ref Target - Figure 3-6

Figure3-6_simplex_both_power_on_hF-34PDF_t.jpg

For normal operation, follow the Aurora 64B/66B simplex normal operation reset sequence.