The TEMAC Receive Configuration Word 1 (RCW1) register is
shown in the following figure. This register can be written at any time but the receiver logic
only applies the configuration changes during inter-frame gaps. The exception to this is the
Reset bit which is effective immediately.
Figure 1. TEMAC Receive Configuration Word 1 (RCW1) Register (0x404)
The following table shows the TEMAC Receive Configuration Word1
register bit definitions.