Start-up latency is the delay between the end of FPGA configuration and the completion of the controller initialization, as marked by entry into the Observation state. This latency is a function of the FPGA size (frame count) and the solution clock frequency.

The start-up latency is incurred only once. It is not part of the mitigation process. The following tables illustrate start-up latency, decomposed into sub-steps of boot and initialization.

Table 1. Maximum Start-up Latency at ICAP FMax for UltraScale Devices
Device Boot Time at ICAP FMax (ms) Initialization Time at ICAP FMax (ms)
UltraScale XCKU035 127 52
XCKU040 1 127 52
XCKU060 127 75
XCKU085 127 75
XCKU095 127 109
XCKU115 127 75
XCVU065 127 75
XCVU080 127 109
XCVU095 127 109
XCVU125 127 75
XCVU160 127 75
XCVU190 127 75
XCVU440 127 156
  1. Measured in hardware. Data for other devices in this architecture are extrapolated based on this measurement
Table 2. Maximum Start-up Latency at ICAP FMax for UltraScale+ Devices
Device Boot Time at ICAP FMax (ms) Initialization Time at ICAP FMax (ms)
UltraScale+ XCKU3P 127 46
XCKU5P 127 46
XCKU9P 127 71
XCKU11P 127 73
XCKU13P 127 85
XCKU15P 127 111
XCVU3P 1 127 84
XCVU5P 204 137
XCVU7P 204 137
XCVU9P 1 204 137
XCVU11P 204 150
XCVU13P 204 153
XCVU27P 204 150
XCVU29P 204 150
XCVU31P 127 97
XCVU33P 127 97
XCVU35P 204 150
XCVU37P 204 150
XCVU45P 204 150
XCVU47P 204 150
XCZU1 127 16
XCZU2 127 16
XCZU3 127 16
XCZU4 127 27
XCZU5 127 27
XCZU6 127 71
XCZU7 127 66
XCZU9 127 71
XCZU11 127 73
XCZU15 127 85
XCZU17 127 111
XCZU19 127 111
UltraScale+ (Continued) XCZU21DR 127 106
XCZU25DR 127 106
XCZU27DR 127 106
XCZU28DR 127 106
XCZU29DR 127 106
XCZU46DR 127 106
XCZU47DR 127 106
XCZU48DR 127 106
XCZU49DR 127 106
U55N 204 150
U55C 204 150
XCVU57P 204 150
XCVU19P 204 153
XCVU15P 204 153
XCVU23P 127 97
XCK26 127 27
XCUX35 127 97
XCAU25P 127 46
XCAU20P 127 46
XCAU15P 127 46
XCAU10P 127 46
  1. Measured in hardware. Data for other devices in this architecture are extrapolated based on this measurement.

The start-up latency is the sum of the boot and initialization latency. The start-up latency at the actual frequency of operation can be estimated using data from the previous tables, and the following equation.

Figure 1. Start-Up Latency