With AXI4-Lite Interface - 3.1 English

UltraScale+ Devices Integrated 100G Ethernet Subsystem Product Guide (PG203)

Document ID
PG203
Release Date
2023-11-01
Version
3.1 English

1.Write the below registers:

0x00014 : 32'h00000001 [CONFIGURATION_RX_REG1 for ctl_rx_enable]

0x0000C : 32'h00000010 [CONFIGURATION_TX_REG1 for ctl_tx_send_rfi]

2.Wait for RX_aligned then write the below registers:

0x0000C : 32'h00000001 [CONFIGURATION_TX_REG1 for ctl_tx_enable to 1’b1 and ctl_tx_send_rfi to 1’b0]

3.When TX/RX flow control is enabled in the Vivado IDE (the default setting), write the registers below.

Note:   If you have disabled TX/RX flow control in the Vivado IDE, skip to step 4.

0x0084 : 32'h00003DFF [CONFIGURATION_RX_FLOW_CONTROL_CONTROL_REG1]

0x0088 : 32'h0001C631 [CONFIGURATION_RX_FLOW_CONTROL_CONTROL_REG2]

0x0048 : 32'hFFFFFFFF [CONFIGURATION_TX_FLOW_CONTROL_QUANTA_REG1]

0x004C : 32'hFFFFFFFF [CONFIGURATION_TX_FLOW_CONTROL_QUANTA_REG2]

0x0050 : 32'hFFFFFFFF [CONFIGURATION_TX_FLOW_CONTROL_QUANTA_REG3]

0x0054 : 32'hFFFFFFFF [CONFIGURATION_TX_FLOW_CONTROL_QUANTA_REG4]

0x0058 : 32'h0000FFFF [CONFIGURATION_TX_FLOW_CONTROL_QUANTA_REG5]

0x0034 : 32'hFFFFFFFF [CONFIGURATION_TX_FLOW_CONTROL_REFRESH_REG1]

0x0038 : 32'hFFFFFFFF [CONFIGURATION_TX_FLOW_CONTROL_REFRESH_REG2]

0x003C : 32'hFFFFFFFF [CONFIGURATION_TX_FLOW_CONTROL_REFRESH_REG3]

0x0040 : 32'hFFFFFFFF [CONFIGURATION_TX_FLOW_CONTROL_REFRESH_REG4]

0x0044 : 32'h0000FFFF [CONFIGURATION_TX_FLOW_CONTROL_REFRESH_REG5]

0x0030 : 32'h000001FF [CONFIGURATION_TX_FLOW_CONTROL_CONTROL_REG1]

4.Data transmission and reception can be performed.