These sub blocks contain the per port TX and RX timers that are typically clocked by their respective TX and RX PHY clocks (tx_phy_clk and rx_phy_clk). The timer synchronizer IP allows for a maximum of sixteen port timers to be enabled at the time of generation.

These port timers maintain time in both the ToD (48-bit seconds and 30-bits nano-sec) and continuous time/correction field (63-bits CF) formats, and provide outputs synchronized to the tx_phy_clk and rx_phy_clk for use by AMD’s Ethernet IP.

It is expected that each port’s TX and RX clock domains can be asynchronous with respect to the Master timer’s ts_clk clock. The port timers contain synchronization logic to domain cross the PTP System Timer’s load-pulse and timer update values.

As the PTP System Timer is initialized, or synchronized to a high precision reference clock, it in turn pushes its updated timer value to all the port timers that are connected to it. After initialization, the Timer Syncer IP can be configured such that the port timers are continuously kept in-sync with the PTP System Timer’s master ToD value, or the port timers might be independently controlled.