The following are typical clock frequencies for the target devices:
• Virtex ® -7 and Virtex UltraScale™ devices with –2 speed grade or higher: 300 MHz
• Kintex ® -7 and Kintex UltraScale™ devices with –2 speed grade or higher: 300 MHz
• Artix ® -7 devices with –2 speed grade or higher: 150 MHz
• UltraScale™+ devices with -1 speed grade or higher: 300 MHz
• Versal® ACAP devices with -1 Speed grade or higher: 300 MHz
The maximum achievable clock frequency can vary. The maximum achievable clock frequency and all resource counts can be affected by other tool options, additional logic in the device, using a different version of Xilinx ® tools, and other factors.