The following table shows the relationship between the fields in the Vivado® IDE and the User Parameters (which can be viewed in the Tcl Console).

Table 1. Vivado IDE Parameter to User Parameter Relationship
Vivado IDE Parameter/Value 1 User Parameter/Value 1 Default Value
Function: Configuration
Standard Standard LTE
Function: Turbo Decode Code parameters
Algorithm Turbo_Decode_Algorithm MaxScale

Scale

     [1.0, 0.0625:0.0625:0.9375]

Turbo_Decode_Scale

     [0, 1:1:15]

 

12

Function: LDPC Decode Code Parameters
LDPC Decode LDPC_Decode False
Support W>1 Enable_Wgt1 False
Code Definition LDPC_Decode_Code_Definition no_file_loaded
Enable LDPC_Decode_Overrides False
No Final Parity Check LDPC_Decode_No_OPC False

Scale

     [1.0, 0.0625:0.0625:0.9375]

LDPC_Decode_Scale

     [0, 1:1:15]

 

12

Max. Schedule LDPC_Decode_Max_Schedule 0
Function: LDPC Encode Code Parameters
LDPC Encode LDPC_Encode False
Code Definition LDPC_Encode_Code_Definition no_file_loaded
Interface: S_AXI
Interface Parameter_Interface Runtime-Configured
Enable I/Fs Enable_IFs False
Out of Order Out_of_Order False
Interrupts Interrupts False
ECC Interrupts ECC_Interrupts None
Bypass Bypass False
AXI WR Protect AXI_WR_Protect False
CODE WR Protect Code_WR_Protect False
Interface: DIN
Interface DIN_Interface Pre-Configured
Lanes DIN_Lanes 1
Words configuration DIN_Words_Configuration Fixed
Number of words DIN_Words 16
Interface: DOUT
Interface DOUT_Interface Pre-Configured
Lanes DOUT_Lanes 1
Words configuration DOUT_Words_Configuration Fixed
Number of words DOUT_Words 16
Runtime Loading
Physical Utilization Physical_Utilization 100
Throughput Utilization Activity 100
Percentage Loading Percentage_Loading Automatic
Turbo Decoder Percentage Loading TD_PERCENT_LOAD 100
LDPC Decoder Percentage Loading LD_PERCENT_LOAD 0
LDPC Encoder Percentage Loading LE_PERCENT_LOAD 0
Example Design
Generate processor-based example design Include_PS_Example_Design False
Include Encoder instance Include_Encode False
Build Vitis Project Build_SDK_Project False
  1. Parameter values are listed in the table where the Vivado IDE parameter value differs from the user parameter value. Such values are shown in this table as indented below the associated parameter.