The MMCMs and PLLs are outside this subsystem instance.
Select Include Shared Logic in example design if:
• This is the second MIPI CSI-2 TX Subsystem instance in a multi-subsystem design
• You only want to manage one customization of the MIPI CSI-2 TX Subsystem in your design
• You want direct access to the input clocks
To fully utilize the MMCM and PLL, customize one MIPI CSI-2 TX Subsystem with shared logic in the subsystem and one with shared logic in the example design. You can connect the MMCM/PLL outputs from the first MIPI CSI-2 TX Subsystem to the second subsystem.
If you want fine control you can select Include Shared Logic in example design and base your own logic on the shared logic produced in the example design.
This Figure shows the sharable resource connections from the MIPI CSI-2 TX Subsystem with shared logic included (MIPI_ CSI_SS_Master) to the instance of another MIPI CSI-2 TX Subsystem without shared logic (MIPI_ CSI_SS_Slave00 and MIPI_ CSI_SS_Slave01).