AXI4-Lite Interfaces - 1.0 English

MicroBlaze Triple Modular Redundancy (TMR) Subsystem (PG268)

Document ID
PG268
Release Date
2022-04-28
Version
1.0 English

Read from a register that does not have all 0s as a default to verify that the interface is functional. Output s_axi_arready asserts when the read address is valid, and output s_axi_rvalid asserts when the read data/response is valid. If the interface is unresponsive, ensure that the following conditions are met:

The s_axi_aclk and aclk inputs are connected and toggling.

The interface is not being held in reset, and s_axi_areset is an active-Low reset.

The interface is enabled, and s_axi_aclken is active-High (if used).

The main subsystem clocks are toggling and that the enables are also asserted.

If the simulation has been run, verify in simulation and/or a debug feature capture that the waveform is correct for accessing the AXI4-Lite interface.