31:16 |
- |
- |
Reserved (read back 0) |
31:20
1
|
- |
- |
Reserved (read back 0) |
19 |
0 |
RO Clear on Reset |
Flags a common mode under voltage interrupt in the converter
2, 3
|
18 |
0 |
Flags a common mode over voltage interrupt in the converter
2, 3
|
17:16 |
- |
- |
Reserved (read back 0) |
15 |
0 |
RO Clear on Reset |
Flags a FIFO overflow in converter when High |
14 |
0 |
Flags a datapath overflow in converter when High |
13 |
0 |
Flags an overflow on the observation channel FIFO in converter when
High
2
, 3
|
12:4 |
- |
- |
Reserved (read back 0) |
3 |
0 |
RO Clear on Reset |
Flags an Over Range interrupt in converter
2
|
2 |
0 |
RO Clear on Read |
Flags an Over Voltage interrupt in converter
2
|
1:0 |
- |
- |
Reserved (read back 0) |
- 31:16 is Reserved (read back 0) for Gen
1/Gen 2 devices.
-
RF-ADC only.
- Gen 3/DFE only.
|