Field Descriptions - 1.0 English

I2S Transmitter and I2S Receiver LogiCORE IP Product Guide (PG308)

Document ID
PG308
Release Date
2021-11-10
Version
1.0 English
Component Name
The base name of the output files generated for the core. Names must begin with a letter and can be composed of any of the following characters: a- z, 0 to 9, and "_".
Audio Channels
Specify the number of audio channels. Allowed values are 2, 4, 6, and 8.
I2S Data Width
Specify the I2S data width. Allowed values are 16 and 24.
Use 32 bit LR Clock
Enables the transmission of data on the I2S channel with 32-bit SCLK. Valid sample bits are determined by the I2S data width.
FIFO Depth
Specify the depth of the FIFO. Allowed values are 64, 128, 256, 512, and 1024. In case of I2S Transmitter, the data is output on I2S interface only after the FIFO is half-filled.
Enable FIFO Data Count
Select this option to enable the IP to output the FIFO read data count.