User Parameters - 1.1 English

Video Scene Change Detection LogiCORE IP Product Guide (PG322)

Document ID
PG322
Release Date
2023-11-10
Version
1.1 English

The following table shows the relationship between the fields in the AMD Vivado™ IDE and the user parameters (which can be viewed in the Tcl Console).

Table 1. User Parameters
Vivado IDE Parameter/Value 1 User Parameter/Value Default Value
Memory Based MEMORY_BASED 1
Samples per Clock SAMPLES_PER_CLOCK 2
Maximum Data Width MAX_DATA_WIDTH 8
Maximum number of Columns MAX_COLS 8192
Maximum number of Rows MAX_ROWS 4320
AXIMM Data Width AXIMM_DATA_WIDTH 32
AXIMM Address Width AXIMM_ADDR_WIDTH 32
Number Read Outstanding AXIMM_NUM_OUTSTANDING 4
Transaction Burst Length AXIMM_BURST_LENGTH 16
Number of Histogram Bins HISTOGRAM_BITS 64
Maximum Number of Streams MAX_NR_STREAMS 1
Y8 HAS_Y8 1
Y10 HAS_Y10 0
  1. Parameter values are listed in the table where the Vivado IDE parameter value differs from the user parameter value. Such values are shown in this table as indented below the associated parameter.