DeltaSize Register (0x38) - 1.0 English

Audio Clock Recovery Unit LogiCORE IP Product Guide (PG335)

Document ID
PG335
Release Date
2019-05-22
Version
1.0 English

This register allows you to specify the minimum amount by which the value of N or Maud is incremented/decremented internally. For example, if this value is 10 and N=6000, then N would be incremented/decremented by a value of 10 until the DeltaSum limit is hit. In other words, this is the granularity of the variation of N.

Table 1. DeltaSize Register (0x38)
Bit Default Value Access Type Description
31:16 0 RO Reserved
15:0 0 R/W Specify the value of Delta Size.