The status of Write Latency Calibration can also be determined by decoding the CAL_ERROR result according to the table below. Execute the Tcl commands noted in the Manually Analyzing the XSDB Output section to generate the XSDB output containing the signal results.
Error Code | Description | Recommended Debug Step |
---|---|---|
37 | Could not find the data pattern given the amount of movement available. | |
38 | Write Latency found rank to rank skew greater than expected. Check margin for the byte for earlier stages of calibration. Probe the DQS/DQ signals (and DM if applicable). | Check DQS and CK trace lengths for all the ranks. Ensure the maximum trace length is not violated. For debug purposes, try a lower frequency. |
39 | Positive sanity check failed. | Check read data margins from earlier stages of calibration. Check signal integrity during reads on the DQS and DQ. |