The status of Write Per-Bit DQ Deskew can also be determined by decoding the CAL_ERROR result according to the table below. Execute the Tcl commands noted in the Manually Analyzing the XSDB Output section to generate the XSDB output containing the signal results.
Error Code | Description | Recommended Debug Step |
---|---|---|
21 | No valid data found for a given bit in the byte by incrementing DQS ODELAY first and then DQ ODELAY. | Check the alignment of DQS to DQ during a write burst with a scope on the PCB. Check the DQS-to-CK alignment. Check the WRLVL fields in XSDB for a given byte. |
22 | Noise region not found for a given bit in the byte by incrementing DQ ODELAY using step size of 10 taps. | Check for a mapping issue. This usually implies a delay is not moving when it should. Check the connections going to the XPHY and ensure the correct RIU is selected based on the byte being adjusted. |
23 | Noise region not found for a given bit in the byte by incrementing DQ ODELAY using step size of 1 tap. | Check for a mapping issue. This usually implies a delay is not moving when it should. Check the connections going to the XPHY and ensure the correct RIU is selected based on the byte being adjusted. |