- Open the IP Example Design.
- Under Flow Navigator, select Simulation
Settings.
- Select Questa Advanced Simulator as the
Target simulator .
- Browse to the compiled libraries location and set the path
for the Compiled libraries location.
- Under the Simulation tab, set the modelsim.simulate.runtime
to 1 ms (there are simulation RTL directives which stop the simulation after
certain period of time, which is less than 1 ms) as shown in the following
figure. The Generate simulation scripts
only option generates simulation scripts only. To run
behavioral simulation, the Generate simulation scripts only option must be
de-selected.
- Apply the settings and select OK.
- In the Flow Navigator window, select Run Simulation
and Run Behavioral Simulation as shown:
-
Vivado invokes the Questa Advanced Simulator and
simulations are run in the Questa Advanced Simulator tool. For more information, see
the
Vivado Design Suite User Guide: Logic
Simulation (UG900)