PS SYSMON Analog_Bus

Zynq UltraScale+ Device Technical Reference Manual (UG1085)

Document ID
UG1085
Release Date
2023-12-21
Revision
2.4 English

The sensor channels {7:10} are routed through four multiplexers controlled by the PSSYSMON.ANALOG_BUS register. The sensor channels connect to the following voltage nodes.

VCCO_PSIO1

VCCO_PSIO2

PS_MGTRAVCC

PS_MGTRAVTT

The recommended value of the ANALOG_BUS register is 3210h; this value is assumed for the definition of these sensor channels in Table: PS SYSMON Sensor Channels and in other places. The register is programmed to 3201h by the PMU ROM pre-boot code and should be reprogrammed by the FSBL or other software code.

Note:   Once the value is reprogrammed by the FSBL it should be changed.

 

RECOMMENDED:   The ANALOG_BUS register should be set to 3210h in the FSBL code. If the recommended value is not used, the sensor channels {7:10} are remapped and might not be compatible with the system software.

The functionality of the ANALOG_BUS register is illustrated in This Figure.

Figure 9-2:      PS SYSMON Unit Sensor Channels {7:10}

X-Ref Target - Figure 9-2

X19411-sensor-channels.jpg