ITATBCTR0 (FUNNEL3P) Register

Zynq UltraScale+ Devices Register Reference (UG1087)

Document ID
UG1087
Release Date
2024-03-13
Revision
1.10

ITATBCTR0 (FUNNEL3P) Register Description

Register NameITATBCTR0
Offset Address0x0000000EF8
Absolute Address 0x00FE910EF8 (CORESIGHT_SOC_FUNN_0)
Width32
TyperwNormal read/write
Reset Value0x00000000
DescriptionThe Integration Test ATB Control 0 Register performs different functions depending on whether the access is a read or a write:
* a write sets the value of the atvalidm.
* a read returns the value of the atvalidsn signals, where n is defined by the status of the Control register at 0x000.

ITATBCTR0 (FUNNEL3P) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
ATBYTES 9:8rwNormal read/write0x0Determine the status of atbytess of the enabled port in Integration Mode
AFREADY 1rwNormal read/write0x0Determine the status of afreadys input to Integration Mode
ATVALID 0rwNormal read/write0x0Determine the status of atvalids input to Integration Mode