Field Name | Bits | Type | Reset Value | Description |
FPD_SC_EN_2 | 16 | roRead-only | 0x0 | Enables SCAN clear of the FPD. If any fuse is set, SCAN clear will occur on the FPD. If all fuses are not set, a boot error is logged in the PMU. |
FPD_SC_EN_1 | 15 | roRead-only | 0x0 | Enables SCAN clear of the FPD. If any fuse is set, SCAN clear will occur on the FPD. If all fuses are not set, a boot error is logged in the PMU. |
FPD_SC_EN_0 | 14 | roRead-only | 0x0 | Enables SCAN clear of the FPD. If any fuse is set, SCAN clear will occur on the FPD. If all fuses are not set, a boot error is logged in the PMU. |
LPD_SC_EN_2 | 13 | roRead-only | 0x0 | Enables SCAN clear of the LPD. If any fuse is set, SCAN clear will occur on the LPD. If all fuses are not set, a boot error is logged in the PMU. |
LPD_SC_EN_1 | 12 | roRead-only | 0x0 | Enables SCAN clear of the LPD. If any fuse is set, SCAN clear will occur on the LPD. If all fuses are not set, a boot error is logged in the PMU. |
LPD_SC_EN_0 | 11 | roRead-only | 0x0 | Enables SCAN clear of the LPD. If any fuse is set, SCAN clear will occur on the LPD. If all fuses are not set, a boot error is logged in the PMU. |
LBIST_EN | 10 | roRead-only | 0x0 | Enables LBIST during pre-boot |
USR_WRLK_7 | 7 | roRead-only | 0x0 | Locks writing to USER_7 fuses |
USR_WRLK_6 | 6 | roRead-only | 0x0 | Locks writing to USER_6 fuses |
USR_WRLK_5 | 5 | roRead-only | 0x0 | Locks writing to USER_5 fuses |
USR_WRLK_4 | 4 | roRead-only | 0x0 | Locks writing to USER_4 fuses |
USR_WRLK_3 | 3 | roRead-only | 0x0 | Locks writing to USER_3 fuses |
USR_WRLK_2 | 2 | roRead-only | 0x0 | Locks writing to USER_2 fuses |
USR_WRLK_1 | 1 | roRead-only | 0x0 | Locks writing to USER_1 fuses |
USR_WRLK_0 | 0 | roRead-only | 0x0 | Locks writing to USER_0 fuses |