Field Name | Bits | Type | Reset Value | Description |
STATUS | 31 | rwNormal read/write | 0 | Single-shot status bit. Indicates if any of the selected comparators have matched. STATUS must be written to set an initial state when configuring the trace unit, if the single-shot comparator is to be used. |
DV | 2 | roRead-only | 0x0 | Data value comparator support bit. Indicates if the trace unit supports data address with data value comparisons |
DA | 1 | roRead-only | 0x0 | Data address comparator support bit. Indicates if the trace unit supports data address comparisons |
INST | 0 | roRead-only | 0 | Instruction address comparator support bit. Indicates if the trace unit supports instruction address comparisons |