STATUS_FLAG (PSSYSMON) Register

Zynq UltraScale+ Devices Register Reference (UG1087)

Document ID
UG1087
Release Date
2024-03-13
Revision
1.10

STATUS_FLAG (PSSYSMON) Register Description

Register NameSTATUS_FLAG
Offset Address0x00000000FC
Absolute Address 0x00FFA508FC (AMS_PS_SYSMON)
Width16
TyperoRead-only
Reset Value0x00000200
DescriptionAlarm Status, Flag 0.

Out of range alarm status: 0: no alarm. 1: alarm asserted. Read-only.

STATUS_FLAG (PSSYSMON) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
internal_ref 9roRead-only0x1always 1: PS always uses its internal voltage reference.
disabled 8roRead-only0x0PS SysMon Power indicator.
0: enabled.
1: disabled.
State of VCC_PSADC voltage node.
alm_6_3 7:4roRead-only0x0Alarm Status read-bit. Voltage out of range.
Bit [4] Alarm 3, VCC_PSAUX.
Bit [5] Alarm 4, VCCO_PSDDR.
Bit [6] Alarm 5, VCCO_PSIO3.
Bit [7] Alarm 6,VCCO_PSIO0.
ot 3roRead-only0x0Bit [3] Alarm, Temp_LPD Over Temperature (OT).
alm_2_0 2:0roRead-only0x0Alarm Status read-bit.
Bit [0] Alarm 0, Temp_LPD.
Bit [1] Alarm 1, VCC_PSINTLP.
Bit [2] Alarm 2, VCC_PSINTFP.