ZQ0SR (DDR_PHY) Register

Zynq UltraScale+ Devices Register Reference (UG1087)

Document ID
UG1087
Release Date
2024-03-13
Revision
1.10

ZQ0SR (DDR_PHY) Register Description

Register NameZQ0SR
Offset Address0x000000069C
Absolute Address 0x00FD08069C (DDR_PHY)
Width32
TyperoRead-only
Reset Value0x00000000
DescriptionZQ 0 Impedance Control Status Register

ZQ0SR (DDR_PHY) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
Reserved31:14roRead-only0x0Return zeroes on reads.
PD_ODT_SAT13roRead-only0x0Pulldown termination strength code saturated due to termination
strength adjustment setting in ZQ0PR register. Will be zero only in
DDR3 mode. If this is set to 1b1, the adjustment factor or ZPROG
setting for the corresponding segment needs to be scaled.
PU_ODT_SAT12roRead-only0x0Pullup termination strength code saturated due to termination
strength adjustment setting in ZQ0PR register. Will be zero only in
DDR3 mode. If this is set to 1b1, the adjustment factor or ZPROG
setting for the corresponding segment needs to be scaled.
PD_DRV_SAT11roRead-only0x0Pulldown drive strength code saturated due to drive strength
adjustment setting in ZQ0PR register. Will be non-zero only in DDR4
mode. If this is set to 1b1, the adjustment factor or ZPROG setting
for the corresponding segment needs to be scaled.
PU_DRV_SAT10roRead-only0x0Pullup drive strength code saturated due to drive strength
adjustment setting in ZQ0PR register. Will be non-zero only in DDR4
mode. If this is set to 1b1, the adjustment factor or ZPROG setting
for the corresponding segment needs to be scaled.
ZDONE 9roRead-only0x0Impedance Calibration Done: Indicates that the first round of
impedance calibration has completed. Any time impedance
calibration is restarted (after a ZCAL bypass exit or ZCAL
configuration register write), this bit goes back to '0' till all segments
are re-calibrated, following which this bit returns to '1'.
ZERR 8roRead-only0x0Impedance Calibration Error: If set, indicates that there was an error
during impedance calibration.
OPU 7:6roRead-only0x0On-die termination (ODT) pull-up calibration status. Valid status
encodings are:
2b00 = Completed with no errors
2b01 = Overflow error
2b10 = Underflow error
2b11 = Calibration in progress
OPD 5:4roRead-only0x0On-die termination (ODT) pull-down calibration status. Valid status
encodings are:
2b00 = Completed with no errors
2b01 = Overflow error
2b10 = Underflow error
2b11 = Calibration in progress
ZPU 3:2roRead-only0x0Output impedance pull-up calibration status. Valid status encodings
are:
2b00 = Completed with no errors
2b01 = Overflow error
2b10 = Underflow error
2b11 = Calibration in progress
ZPD 1:0roRead-only0x0Output impedance pull-down calibration status. Valid status
encodings are:
2b00 = Completed with no errors
2b01 = Overflow error
2b10 = Underflow error
2b11 = Calibration in progress